Skip to main content

Table 2 Sensitivity for detecting occult pneumothorax of oblique chest radiograph vs. lung ultrasonography viewed in terms of size of occult pneumothorax

From: Diagnostic accuracy of oblique chest radiograph for occult pneumothorax: comparison with ultrasonography

 

Occult pneumothorax size (n = 70)

 

Minuscule

Anterior

Anterolateral

n = 19

n = 32

n = 19

Oblique X-ray sensitivity (%)

15.8

68.8

94.7

Lung US sensitivity (%)

10.5

75.0

94.7

p

0.63

0.59

1.0

Need for chest tube (%)

10.5

40.6

89.5