Skip to main content

Table 1 Time to first leakage and to 100% leakage of double-lumen tubes at each intra-cuff pressure

From: Prevention of lung-to-lung aspiration during emergency thoracic surgery: an experimental study

Group

Time to first leakage (s)*

Corrected P-value*

Time to 100% leakage (min)

Corrected P-value

25

21.0 (7.0-59.0)

0.495a

3.0 (2.0-4.0)

0.786a

50

48.0 (32.0-78.0)

0.002b

6.0 (4.0-12.0)

0.002b

100

191 (125.0-260.0)

0.002c

85.0 (70.0-130.0)

0.002c

  1. Data are presented as median (interquartile).
  2. Group 25: Intra-cuff pressure of 25 cm H2O; group 50: Intra-cuff pressure of 50 cm H2O; group 100: Intra-cuff pressure of 100 cm H2O.
  3. *P = 0.001 among all three groups.
  4. P < 0.001 among all three groups.
  5. aGroup 25 vs. group 50.
  6. bGroup 50 vs. group 100.